How a backflow valve works
In normal operation the outflowing water pushes the flap open. When the flow reverses, it drops shut and seals the pipe. It also has an emergency closure you can lock by hand, for example before a holiday or when backflow is forecast.
DIN EN 13564 distinguishes several types. For a basement these matter most:
- Type 2 — two automatic closures, one of which can also be locked by hand (emergency closure), for wastewater without faeces such as washing machine, shower or basin
- Type 3 marked "F" — a power-operated closure plus an independent emergency closure. Only this type is approved for wastewater containing faeces, that is for a toilet in the basement.
- Type 5 — built into a floor drain, likewise with two automatic closures. This is the classic "floor drain with backflow valve".
A note on wording: people often say non-return flap. Off-the-shelf non-return flaps are frequently something else, namely check valves screwed onto a pump's discharge port to stop the pressure line draining back. They protect the pump, not the basement against sewer backflow. If you need backflow protection, look for a tested product to DIN EN 13564 in the right type.
Water in the basement despite a backflow valve: why?
Having a valve is no free pass. These causes are usually behind it:
- The valve was dirty — grease, limescale, hair or a stone on the sealing face is enough. The flap drops shut but does not seal.
- Only one closure instead of two — types 2, 3 and 5 are intended for wastewater without faeces, that is devices with two automatic closures or with power operation. Older single flaps offer less safety.
- Not every drain is protected — often only one drain sits behind the valve. When the sewer fills up, the water arrives via the unprotected floor drain, the basement shower or an old, forgotten pipe.
- Wrong type for faeces — for a toilet below the backflow level, only type 3 marked "F" is permitted. If the drain is needed during backflow, or substantial property is in the room, a lifting station is required anyway.
- It was not backflow at all — if clear, odourless water comes through the base slab or the wall joint, it was groundwater. If it runs in during the rain via a light well or the basement stairs, it was surface water. No backflow valve helps against either.
- The emergency closure was open — it does not replace maintenance, but when heavy rain is forecast it is the last reserve.
The uncomfortable part: a fault in a backflow valve usually only shows up during an actual backflow, and by then it is too late. That is why maintenance is not paperwork but the actual protection.
Maintenance: twice a year
Information sheets from municipal wastewater utilities and the German federal flood protection guide name twice a year as the servicing interval for backflow valves. On top of that comes a monthly visual check in which you operate the emergency closure. With electrically operated type 3 units, that belongs in the hands of a specialist firm.
What servicing involves:
- Clean flaps and sealing faces, remove deposits
- Check seals for cracks and hardening, replace as needed
- Check that the closures move freely, keep the mechanism working
- Operate the emergency closure so it does not seize
- On electric units, check the control, the alarm and the backup power supply
Keep the records. If you are insured against backflow damage, the insurer may ask for proof of adequate maintenance when you claim. Experience shows this is exactly the point people overlook.
What Drainbee can and cannot do here
Drainbee measures the water level in a pump sump or in the collecting chamber of a lifting station, to ± 1 cm over a range of 0 to 1 m. If your basement drains via such a shaft, the app shows you how it behaves in heavy rain: whether the level rises unusually, how often the pump switches and how much water flows in. You get alarms on threshold, power outage and Wi-Fi loss, as a push notification or a call-style alarm in the app. Price: €298 once, no subscription.
To stay honest about it: Drainbee does not check whether your backflow valve seals properly. It does not sit in the wastewater pipe and knows nothing about the state of the sealing faces. If water enters a room without a shaft through an unprotected floor drain, the sensor measures none of it. For water on the floor, a water leak detector is the right device.
The backflow valve keeps the sewer water out. Servicing it twice a year keeps it working. And a level sensor in the shaft shows you how much reserve your basement still has in heavy rain.
Frequently asked questions
Why do I have water in the basement despite a backflow valve?
How often must a backflow valve be serviced?
Is a backflow valve enough for a toilet in the basement?
What happens if the backflow valve does not close?
Sources
- DNWAB: Kundeninformation Rückstauverschlüsse nach EN 12056, DIN 1986-100 und EN 13564 (2024) (opens in a new tab)
- DIN Media: DIN EN 13564-1 Rückstauverschlüsse für Gebäude – Teil 1: Anforderungen (opens in a new tab)
- BMWSB: Hochwasserschutzfibel – Objektschutz und bauliche Vorsorge (2022) (opens in a new tab)
- Verbraucherzentrale: Starkregen-Überflutung und Rückstau: So läuft das Haus nicht voll Wasser (2026) (opens in a new tab)