Why a pump failure often goes unnoticed
A basement pump works in bursts. In our analysis of 8 Drainbee pump sumps in residential buildings (19 March to 6 October 2026, 1,616 device-days), the pump did not run at all on 62% of days. On days when it ran, the median was 4 pump cycles, with up to 49 on individual days. On its busiest day, a device’s pump ran about 7 times as often as on a typical pump day.
This is a small sample from our own fleet, not representative. The pattern is clear all the same: long quiet spells, then a lot of work all at once. If the pump fails during a quiet phase, nobody notices, because it would have had nothing to do anyway. The fault only becomes visible when the water arrives. And then in a volume that fills the pit quickly.
What a pump failure costs
How expensive an overflowing pump sump gets depends on the volume of water, the floor construction and how long the water stands. There are no reliable figures specifically for pump failures. Insurers’ figures help put it in context:
- Heavy-rain damage to residential buildings cost affected homeowners €7,600 on average, and €11,000 on average in Rhineland-Palatinate (GDV, 2002–2021).
- An insured natural hazard claim, for example from flooding, heavy rain or sewer backflow, cost around €4,700 on average in 2025 (GDV).
- Around 41% of residential buildings in Germany had no natural hazard cover at the end of 2025 (GDV).
Whether water from an overflowing pump sump is covered by your natural hazard insurance at all depends on your policy. Check your terms before it happens. And the longer the water stands, the further it soaks into screed and walls. What to do next is covered under water damage.
The most common causes of pump failure
The troubleshooting tables in manufacturers’ manuals list the same causes again and again. Here they are, sorted by what you see:
The pump does not start
- No power: power cut, fuse or RCD tripped, plug pulled, cable damaged
- Float switch stuck on the wall, a cable or the pressure pipe, or held down by sludge
- Motor protection has tripped due to overheating, a blocked impeller or a voltage fault
- Motor faulty
The pump runs, but the level does not drop
- Impeller dirty or worn, for example from sand
- Pressure pipe clogged or hose kinked
- Air in the pump housing because the vent opening is blocked
The pump runs constantly or cycles
- Float stuck in the up position and no longer switching off: the pump runs dry and can overheat
- Leaking non-return valve: water from the pressure pipe flows back and the pump keeps restarting
- Unusually high inflow, for example with rising groundwater
There is no reliable blanket figure for the lifespan of a basement pump in years. How long a pump lasts depends on how much sand and sludge it moves, how often it switches and how well it is maintained.
Warning signs: How to spot an impending pump failure
- New noises: grinding, rattling or humming without pumping point to a worn bearing or a blocked impeller.
- Longer run times: the pump takes noticeably longer than before to lower the level in the pit.
- Frequent cycling: the pump starts more often than usual even though it has stopped raining.
- Higher resting level: the water stays higher in the pit than normal.
- RCD trips: if this happens repeatedly for no obvious reason, an insulation fault in the motor or cable may be behind it. A job for a qualified electrician.
Without measurements, you will only notice most of these signs if you happen to be standing next to the pit. If you record pump cycles and the level history, you can see changes over weeks.
Pump has failed: what to do now
- Safety first. If there is water in the room and sockets, distribution boards or appliances are within reach, do not go in. Switch off the power at the fuse box if it is outside the wet area. Otherwise call the fire brigade or the grid operator.
- Narrow down the cause. Fuse, RCD, plug. Then lift the float: does the pump start?
- Unplug first, then touch. Clean the impeller and intake strainer only with the power off.
- Emergency operation. If the pump will not run again, pump the water out with a spare or hired pump. A second submersible pump kept in the basement as a reserve saves time in an emergency.
- Document. Take photos of the water level, the damage and the pump, and note the time.
- Inform your insurer. Report the damage without delay, as section 30 of the German Insurance Contract Act (VVG) requires.
- Dry out. Ventilate and dehumidify as soon as possible, and bring in a specialist building-drying company if the screed is soaked.
Prevention: maintenance, backup and alarm
In the manual for its Kompaktboy lifting station, Zehnder says, in essence: any electrical appliance can fail due to a power cut or a defect. If that could cause you damage, you should plan for an emergency generator, a manual diaphragm pump, a second unit and/or a mains-independent alarm. The same applies to a pump sump.
- Test regularly: function test with a bucket of water, free the float, clean the intake strainer. The full checklist is under pump sump.
- Spare pump: a second submersible pump with a suitable hose ready to hand in the basement.
- Second pump in the pit: with high inflow, a permanently installed second pump that switches on slightly higher.
- Independent alarm: a level sensor or a high-water float with an alarm unit that does not depend on the pump’s own float. More under float switch.
How Drainbee reports a pump failure
Drainbee measures the water level in the pump sump with a hydrostatic probe (0–1 m, ± 1 cm), adaptively every 10 seconds to 5 minutes. If the pump fails, the level keeps rising instead of dropping again after the switch-on point. When it passes your threshold, you get an alarm by push notification or call-style alarm in the app, before the pit overflows. You also get an alarm on power outage and on Wi-Fi loss.
The app also shows you the pump cycles and the level history. If the pump starts more often than usual or the level drops more slowly, you can spot it there yourself, often before the pump fails completely. Drainbee cannot control the pump. It is a second, independent layer alongside the float.
Frequently asked questions
How do I detect a pump failure?
How much does water damage from pump failure cost?
Can I prevent pump failure?
Does insurance pay for a pump failure?
Sources
- GDV: Starkregen nach Gewittern: 41 Prozent der Wohngebäude ohne Elementarschutz (2026) (opens in a new tab)
- GDV: Starkregenbilanz 2002 bis 2021: Bundesweit 12,6 Milliarden Euro Schäden (2023) (opens in a new tab)
- Zehnder Pumpen: Gebrauchsanleitung ZPK / S-ZPK (2023) (opens in a new tab)
- Zehnder Pumpen: Gebrauchsanleitung Kompaktboy Einzel (2020) (opens in a new tab)
- Versicherungsvertragsgesetz (VVG): § 30 Anzeige des Versicherungsfalles (opens in a new tab)